Powered, wall-to-wall thrombectomy
that adjusts to the vessel

Powered,
wall-to-wall thrombectomy
that adjusts to
the vessel

The dual-action Pounce™ Venous Thrombectomy System rapidly removes large quantities of fresh or organized, wall-adherent clot from peripheral veins while allowing focal treatment of thrombosed vessels. No thrombolytics needed.

≥10 Fr sheath
compatibility

6–16mm vessel
diameter range

Basket can be narrowed or fully collapsed

Removes organized clot with low-profile system.

Self-adjusting, manually collapsible basket.

Simple to use.
No capital equipment.

ENDOVASCULAR TODAY

READ THE ARTICLE

The 10 Fr Pounce™ Venous Thrombectomy System: designed for power and operator control


Read past Endovascular Today supplements:

Clinical data

Results from a prospective, nonrandomized, multicenter, first-in-human study of 19 patients with acute vein thrombosis followed to 12 months.1 No SAEs or device-related complications were reported.

EFFICACY


100%

Procedural success in single-session2

SPEED


23 minutes

Median thrombectomy time3

PTS (12 MONTH)


0%

Freedom from moderate to severe PTS4

  1. Black SA, Thulasidasan N, Benton L, et al. Single-session mechanical thrombectomy for iliofemoral deep vein thrombosis using a dual mechanism of action device combining basket and rotational thrombectomy. J Vasc Surg Venous Lymphat Disord. 2024;12(5):101866.
  2. Based on primary end point clot removal success being SIR Grade II Lysis or better.
  3. Thrombectomy time defined as introduction of Pounce Venous Thrombectomy System to final device removal (includes imaging assessments between passes where applicable).
  4. Post-thrombotic syndrome (PTS) at 12-month follow up (N=11) defined as clinically significant PTS scored via Villalta score as being severe (>=15) or moderate (10-14).

How it works

Power

Rotational Extraction Screw Technology Designed to macerate and extract thrombus
at the point of collection. Watch animation

Control

Dynamic Basket Technology
Self-adjusting basket maintains wall contact.
Can be manually collapsed. Watch animation

CASE REPORT

Grab, go, restore flow

Removal of
mixed-morphology
clot in lower
extremity veins
5

Initial venogram:
occlusive fem-pop clot

Final venogram:
restored blood flow

Organized clot removed
(3 passes)

  1. Patel N. The Pounce™ Venous Thrombectomy System: Power and Control for Removing Peripheral Venous Clot. Presented at: 37th Annual International Symposium on Endovascular Therapy (ISET); February 2-5, 2025; Hollywood, FL.

Intended Use:

The device is indicated for mechanical de-clotting and controlled, and selective infusion of physician specified fluids, including thrombolytics, in the peripheral vasculature.

Contraindications:

  • Patients contraindicated for endovascular procedures
  • Patients who cannot tolerate contrast media
  • Patients in whom the lesion cannot be accessed with the guide wire
  • Veins less than 6 mm diameter