
Next generation power and control
The dual-action Pounce™ Venous Thrombectomy System rapidly removes large quantities of fresh or organized, wall-adherent clot from peripheral veins while allowing focal treatment of thrombosed vessels. No thrombolytics needed.
≥10 Fr sheath
compatibility
6–16mm vessel
diameter range
Basket can be narrowed or fully collapsed

How can a 10 Fr system with a 3-4 cm basket remove so much clot? Dual action.
The spring-tensioned basket disrupts wall-adherent thrombus, while the rotational extraction screw macerates and removes it.
Next-generation venous thrombectomy
Effective for acute thrombus1
Wall apposition for
adherent clot
Powered mechanical maceration
Powered thrombus
extration
Self-adjusting, collapsible basket
- Black SA, Thulasidasan N, Benton L, et al. Single-session mechanical thrombectomy for iliofemoral deep vein thrombosis using a dual mechanism of action device combining basket and rotational thrombectomy. J Vasc Surg Venous Lymphat Disord. 2024;12(5):101866.
Next-generation
venous thrombectomy
Effective for acute thrombus1
Wall apposition for adherent clot
Powered mechanical maceration
Powered thrombus extration
Self-adjusting, collapsible basket
- Black SA, Thulasidasan N, Benton L, et al. Single-session mechanical thrombectomy for iliofemoral deep vein thrombosis using a dual mechanism of action device combining basket and rotational thrombectomy. J Vasc Surg Venous Lymphat Disord. 2024;12(5):101866.

CASE REPORT
Grab, go, restore flow
Efficient subclavian vein thrombus removal2
Initial venogram:
occlusive fem-pop clot
Final venogram:
restored blood flow
Fresh clot removed
(2 passes)
- Griffin J. Tackling Venous Thrombus with Dual-Action Thrombectomy. Endovasc Today (digital insert). 2023;22(10).
Grab-and-go mechanical thrombectomy
The Pounce™ Venous Thrombectomy System is engineered specifically for the unique requirements of venous disease interventions.
Model Number | Sheath Compatibility |
---|---|
VTS-0018-09010 | 10 Fr (3.3 mm) |
Guidewire Compatibility |
---|
0.018" OTW |
Working Length | Vessel Range |
---|---|
90 cm | 6 - 16 mm |
Model Number | Sheath Compatibility |
Guidewire Compatibility |
Working Length | Vessel Range |
---|---|---|---|---|
VTS-0018-09010 | 10 Fr | 0.018" OTW | 90 cm | 6 - 16 mm |
Download the Pounce Venous System brochure to view full product specifications
Intended Use:
The device is indicated for mechanical de-clotting and controlled, and selective infusion of physician specified fluids, including thrombolytics, in the peripheral vasculature.
Contraindications:
- Patients contraindicated for endovascular procedures
- Patients who cannot tolerate contrast media
- Patients in whom the lesion cannot be accessed with the guide wire
- Veins less than 6 mm diameter